ZW Series

models in this series

Spot diameter sizes range from 190 µm down to 4 µm, improving the ability scan minute profiles
Small spot diameter down to 9µm improving the ability to measure minute profiles
Constant spot diameter throughout total measuring range
Slim form factor pen and 90⁰ elbow types – fits anywhere
Response time as fast as 20µs - Enables high-speed sampling during motion 
High Resolution of  0.25µm allows hairline pattern measurements or irregular surfaces
Linearity down to ±0.3µm regardless of material type, as a result no tuning is required
Superb angle compensation of ±25⁰ makes the measurement of round or inclined surfaces possible
Machine control integration made easy with available DLL files

Local Stock Centre
Call Our Local Support Team
Fast and Trackable Delivery

Models

Models

There are models in this series

Show
Sort by

Accessories

Accessories

There are accessories in this series

Show
Sort by

Downloads

Downloads

Enquire

Enquire

Articles for this series

You can find articles written by our team here to help you on your journey with us. They contain useful tips, startup guides and best practice configuration for our products.

June 16, 2024

How to Configure NTP for CP1L/NX series PLCs

Introduction A NTP (Network Time Protocol) server is a specialized network server that provides accurate time information to connected devices. It synchronizes the clocks of computers and other devices over a network, ensuring that all devices mainta

February 19, 2024

Connecting a CP1L/H PLC to an NB HMI using a CP1W-EIP61 Option Board

Introduction This guide will show the process of connecting a CP1L or CP1H PLC to an NB HMI using a CP1W-EIP61 option board. Normally the connection of a CP1L or CP1H to an HMI is documented assuming the use of an NS HMI, or a CP1W-CIF41 option board

November 28, 2023

CP and NJ FINS TCP Sample Code

Most models of OMRON PLC support FINS commands, which can allow you to transmit data from one PLC to another. These commands are cross platform compatible, so a CP series PLC can communicate to an NJ series PLC via FINS. The SEND(Send) command allows

November 06, 2024

ZEN Transition Guide

Introduction This article aims to help users transition from the discontinued ZEN relays, to the PLC based alternative using the CP1W-DAM01 LCD option board. This option board can be used with CP1L and CP1H series PLC's (excluding CP1L-L10). The user

Start a Conversation
This conversation is closed
Uploading...